Agincourt Low-Rise Magic-Pak Two-Floor Replacement
A documented project record from Condo HVAC Repair Toronto. An Agincourt low-rise had original 1990s gas Magic-Pak units on two floors, with compressor failures and one Enbridge Red Tag in the previous winter. The facilities director wanted both floors done at once at bulk pricing.
By The Condo HVAC Repair Toronto Crew
Project Attributes
- Scope
- Replace 16 original 1990s Magic-Pak units with MGE series, new louvers, gas sign-off per suite
- Price
- $92,800 CAD
- Payment
- 50% deposit, balance at sign-off (bulk 10+ pricing)
- Lead time
- 5 weeks
- On site
- 8 working days
- Client
- Facilities director, condo corporation
- Crew
- David Okonkwo (Ops Mgr) + 3 technicians
- Equipment
- Magic-Pak MGE series
- Neighbourhood
- Agincourt
- Building
- 16 suites over 2 floors, 1990s construction
The Challenge
The units were original to the building and parts were getting hard to source. One unit had been Red Tagged by Enbridge for a heat exchanger issue, leaving the suite without heat until a replacement was arranged.
Residents needed heat back the same evening, so each suite had to be removed, set, vented, gas-tested and signed off in a single working day.
Results
- 16 units replaced in 8 working days at bulk 10+ pricing.
- Every suite had heat back by evening on its install day.
- Red Tag cleared with code-compliant replacement and paperwork.
- Old units removed and disposed of by the crew.
How We Ran It
- 1
Site survey and louver check
David Okonkwo measured every closet opening and louver. The MGE series fit the existing openings, and new louvers were ordered to match the wall sleeve depth.
- 2
Two suites per day
A crew of three removed the old unit, set the new one, connected gas, venting and condensate, then started and tested it. The gas technician completed sign-off before leaving each suite.
- 3
Red Tag closed out
The tagged suite was scheduled first so the documentation could be filed and the tag cleared with the new equipment in place.
Project Photos
Click any photo to enlarge it.
"Swapped 16 Magic-Pak units on two floors with gas sign-off done the same day for each suite. Residents had heat back by evening every time."
Rob H., Facilities director, Agincourt
More Condo HVAC Projects
Yorkville Yorkville 42-Unit Tower
Annual Fan Coil Service Program
- Scope
- 42 coil descales + 4 pumps + 11 valves
- On site
- 3 service nights across 2 weeks
- Crew
- Marcus Chen (Ops Mgr) + 4 technicians
- Equipment
- McQuay vertical fan coils, 2001 vintage
- Neighbourhood
- Yorkville
Mimico Mimico 180-Unit Lakefront
Building-Wide Fan Coil Replacement
- Scope
- Rolling fan coil replacement
- On site
- 14-week rolling install
- Crew
- Elena Vargas (Ops Mgr) + 2 crews
- Equipment
- Replacement vertical fan coils with ECM motors
- Neighbourhood
- Mimico
Downtown Markham Downtown Markham 24-Unit Mid-Rise
Water-Source Heat Pump Repair
- Scope
- Reversing valves + contactors
- On site
- 6 days over one season
- Crew
- James Kowalski (Ops Mgr) + 2 technicians
- Equipment
- Trane Axiom water-loop heat pumps
- Neighbourhood
- Downtown Markham
Planning Work Like This in Your Building?
Start with a free walk-through and readings in sample suites. Your board gets a written scope, per-unit pricing and a schedule before anyone commits.
- Written scope before work
- TSSA + Enbridge Red Tag + ESA + WSIB
- Written workmanship warranty