# Downtown Markham 24-Unit Mid-Rise Heat Pump Repair | Condo HVAC Repair Toronto

URL: https://condohvacrepairtoronto.ca/projects/downtown-markham-24-unit-heat-pump-repair/
Last-Modified: 2026-10-09
Author: The Condo HVAC Repair Toronto Crew

Condo Heat Pump Repair | Downtown Markham

# Downtown Markham 24-Unit Mid-Rise Heat Pump Repair

A documented project record from 

Condo HVAC Repair Toronto

[/ →](/)

. A 24-unit Downtown Markham mid-rise had heat pumps stuck in one mode at the spring changeover and a run of contactor failures mid-season. A previous contractor had suggested chassis replacement for several units. The diagnostic showed most of them only needed valves and contactors.

By The Condo HVAC Repair Toronto Crew

$14,200 CAD 6 days over one season 24 suites

![Technicians sliding a Trane water-source heat pump chassis out of a condo closet in Markham](/images/misc/two-technicians-sliding-a-trane-water-source-heat-.webp)

Project Record

## Project Attributes

Scope

Single-season water-source heat pump repair: reversing valves and contactors

Price

$14,200 CAD

Payment

Progress invoiced, net 30

Lead time

1 week

On site

6 days over one season

Client

Property manager (24-unit mid-rise)

Crew

James Kowalski (Ops Mgr) + 2 technicians

Equipment

Trane Axiom water-loop heat pumps

Neighbourhood

Downtown Markham

Building

24 suites, 2000s construction

## The Challenge

At changeover, several suites were stuck in heating mode with the building loop already on cooling temperatures. Mid-season, three compressors stopped on the same week, each with a pitted contactor.

The property manager had a quote recommending chassis swaps that would have cost well over the annual repair budget.

### Results

-   No chassis replacements needed on the units originally flagged.
-   All 24 suites cooling and heating correctly through the season.
-   Progress invoiced on net 30 terms, within the annual repair budget.
-   Building moved onto an annual service contract with the same team.

## How We Ran It

1.  1
    
    ### Loop first, unit second
    
    James Kowalski checked loop supply temperature, flow and strainers before touching any chassis. The loop was healthy, which put the problem squarely in the units.
    
2.  2
    
    ### Reversing valve testing
    
    Solenoid coils were tested for voltage and resistance, then valve shift was confirmed on gauges. Valves that would not shift were replaced with refrigerant recovered and recharged by weight.
    
3.  3
    
    ### Contactor and capacitor sweep
    
    Every unit in the building had its contactor and run capacitor checked, so the remaining failures were caught before they stopped a compressor.
    

On Site

## Project Photos

Click any photo to enlarge it.

 

Related

## More Condo HVAC Projects

Condo Heat Pump Repair service

[/condo-heat-pump-repair/ →](/condo-heat-pump-repair/)

 

Condo HVAC in Markham

[/locations/markham/ →](/locations/markham/)

 

![Two technicians descaling an open McQuay vertical fan coil in a Yorkville condo suite](/images/misc/two-hvac-technicians-in-navy-workwear-descaling-an.webp) Yorkville

### Yorkville 42-Unit Tower

Annual Fan Coil Service Program

$38,500 CAD

Scope

42 coil descales + 4 pumps + 11 valves

On site

3 service nights across 2 weeks

Crew

Marcus Chen (Ops Mgr) + 4 technicians

Equipment

McQuay vertical fan coils, 2001 vintage

Neighbourhood

Yorkville

View full project record

[Yorkville 42-Unit Tower →](/projects/yorkville-42-unit-annual-service/)

 

![Crew setting a new vertical fan coil cabinet in a Mimico lakefront condo suite](/images/misc/hvac-crew-of-three-setting-a-new-vertical-fan-coil.webp) Mimico

### Mimico 180-Unit Lakefront

Building-Wide Fan Coil Replacement

$186,000 CAD

Scope

Rolling fan coil replacement

On site

14-week rolling install

Crew

Elena Vargas (Ops Mgr) + 2 crews

Equipment

Replacement vertical fan coils with ECM motors

Neighbourhood

Mimico

View full project record

[Mimico 180-Unit Lakefront →](/projects/mimico-180-unit-fan-coil-replacement/)

 

![Technicians lifting a new Magic-Pak MGE unit into a closet in an Agincourt low-rise](/images/misc/three-technicians-lifting-a-new-magic-pak-mge-thro.webp) Agincourt

### Agincourt Low-Rise Magic-Pak

Two-Floor Magic-Pak Replacement

$92,800 CAD

Scope

16 units to MGE series + louvers

On site

8 working days

Crew

David Okonkwo (Ops Mgr) + 3 technicians

Equipment

Magic-Pak MGE series

Neighbourhood

Agincourt

View full project record

[Agincourt Low-Rise Magic-Pak →](/projects/agincourt-magic-pak-floor-replacement/)

![](/images/misc/operations-manager-presenting-a-written-hvac-scope.webp)

24-Hour Condo Emergency Dispatch

## Planning Work Like This in Your Building?

Start with a free walk-through and readings in sample suites. Your board gets a written scope, per-unit pricing and a schedule before anyone commits.

Book a $185 Diagnostic

[/contact/ →](/contact/)

 

Call (647) 294-5454

[tel:+16472945454 →](tel:+16472945454)

-   \* Written scope before work
-   \* TSSA + Enbridge Red Tag + ESA + WSIB
-   \* Written workmanship warranty